Type
FS080ES----single ,visual and audible warning
FS080ER---wireless signal will output after warning
FS080EV---visual and audible warning , self-adjustment, shutting off the electronagnetic valve after warning
FS080EM---shutting off electronagnetic valve ,opening the vent fan after warning.visual and audible warning.
Series -FS0801E is adapted to methane, ,LPG and FS0802E is adapted to coal gas .
technology parameter
target gas natural gas , artificial gas , LPG
alarming concentration < 5 %LEL(methane, ,LPG )
temperature -10℃~55℃(in room)
humidity <95/%
working voltage AC180~270V/50Hz
output of vent fan AC220V/1A
storage temperature -25℃~55℃
stress 86~106Kpa
comsumption static comsumption <1.2W alarm comsumption <2w
validity period 5 years
working place in room
Installation
1, Adapted to Series FS0801E ,annunciator should be fixed about 1m from floor,2cm from wall and 8cm and 4m less than from kitchen ware .
2, Adapted to Series FS0802E , annunciator should be fixed about 30cm from ceiling,2cm from wall , 8cm and 4m less than from kitchen ware .as follows
Notice
1,Gas-leakage annunciator must be fixed the place where easy to be watched and checked.
2,Gas-leakage annunciator must be fixed the room where easy to leak gas ,or not ,there is no alarming.
3,Vibrating 、falling 、striking may cause ineffective.
4,The place of installation must not over against the smell of cooking.
5,Gas-leakage annunciator should be fixed the place of ventilation.
6,Gas-leakage annunciator can not be covered by anything.
7, Gas-leakage annunciator must not be fixed by airconditional and refrigerator.
Direction for using
1,Fixed as the erection instructions
2,when connecting the electrical source , the annunciator can not work when the green light is sparking,
3,when the green light is stable after 3 or 4 mins ,annunciaor is at working.
4,when the red light on and annunciator ringing, it is unworkable.
5,Gas-leakage annunciator will warn for 10 seconds .red light will spark and output on or off signal when the appointed gas concentration reached.
Product detection
1, Gas-leakage annunciator has self-adjustment function . when the red light on and annunciator ringing,it is unworkable..please change immediately.
2,gas-leakage annunciator must be checked each month.
Notice
1,When green light sparking ,whiffing detection is not allowed.
2,Spouting irritative gas as insecticide,
alcohol and paint is not allowed.
3,Please comfire power suply regulaty
4, According to the erection instructions to install ,don’t move or change the place of installation.
Checking
The product should be checked by manufacturer and
appointed manufacturer when unworkable and striping by others is not allowed..the manufacturer will not take charge the
responsibility by striping without permission